Kimo Air Velocity Transmitter Kimo CTV100
Product Description
Kimo Air Velocity Transmitter Kimo Ctv100
Kimo-France
Temperature And Air Velocity Transmitter
Model : Ctv 100
Temperature And Air Velocity Transmitter Type Ctv100.
Ranges From 0-5 M/S To 0-30 M/S And 0 To +50C, -20 To +80C, -50 To +50C, 0 To
+100C (See "Configuration")
0-10 V Or 4-20 Ma Output, Active, Power Supply 24 Vac/Vdc (3-4 Wires)
Abs Ip 65 Housing, With Or Without Display
Alternating Display Of Air Velocity And Temperature
Quick And Easy Mounting 1/4 Turn System With Wall-Mount Plate
Air Velocity:
Units Of Measurement .........M/S And Fpm
Accuracy * ............................3% Of Reading 0,3 M/S
Response Time .....................1/E (63%) 2 Sec.
Resolution ............................0,1 M/S
Type Of Fluid..........................Air And Neutral Gases
Temperature:
Measuring Range...................................0 To +50C, -20 To +80C,-50 To +50C,0 To +100C
Units Of Measurement .......................C, F
Accuracy * ..........................................0,5% Of Reading 0,4C
Response Time ...................................1/E (63%) 5 Sec.
Resolution ..........................................0,1C
Type Of Sensor....................................Pt100 Class A As Per Din Iec751
Type Of Fluid........................................Air And Neutral Gases
Kimo-France
Temperature And Air Velocity Transmitter
Model : Ctv 100
Temperature And Air Velocity Transmitter Type Ctv100.
Ranges From 0-5 M/S To 0-30 M/S And 0 To +50C, -20 To +80C, -50 To +50C, 0 To
+100C (See "Configuration")
0-10 V Or 4-20 Ma Output, Active, Power Supply 24 Vac/Vdc (3-4 Wires)
Abs Ip 65 Housing, With Or Without Display
Alternating Display Of Air Velocity And Temperature
Quick And Easy Mounting 1/4 Turn System With Wall-Mount Plate
Air Velocity:
- Working Principle : The Air Velocity
- Measurement Is Made With A
- Hot Wire, In Constant Thermal
- Equilibrium. The Temperature Is
- Maintained And Measured With A
- Pt 100 Element.
Units Of Measurement .........M/S And Fpm
Accuracy * ............................3% Of Reading 0,3 M/S
Response Time .....................1/E (63%) 2 Sec.
Resolution ............................0,1 M/S
Type Of Fluid..........................Air And Neutral Gases
Temperature:
Measuring Range...................................0 To +50C, -20 To +80C,-50 To +50C,0 To +100C
Units Of Measurement .......................C, F
Accuracy * ..........................................0,5% Of Reading 0,4C
Response Time ...................................1/E (63%) 5 Sec.
Resolution ..........................................0,1C
Type Of Sensor....................................Pt100 Class A As Per Din Iec751
Type Of Fluid........................................Air And Neutral Gases
Related Products
Contact Us
No. 001, Priya Enclave, Beside E-Seva, Road No. 9, Snehapuri Colony, Nacharam, Hyderabad, Telangana, 500076, India
Phone :+918035063233